Public corporation
Mikhnevo Repair and Engineering Works
8-800-550-07-58
E-mail: zavod@mrmz.ru
MachineryElectrical equipmentSpare parts
automatic three-phase circuit breakers VA57f35
 
Low-voltage equipment

Automatic circuit breakers

Single-phase
  • AE1031
  • AE2044
  • A63M

    Two-phase
  • AP50B-2MT

    Three-phase
  • A3716, A3726
  • A3790
  • AE20
  • VA51, VA52
  • VA57f35
  • AP50B-3MT

    For DIN devices
  • VA6026
  • IEK VA4729

  • Contactor switches
  • KT60

    Break switches

    Button switches
  • KE

    Rotary switches
  • PV, PVP

    Terminal (position) switches
  • VPK
  • VPU

    Push-button control stations
  • PKT
  • PKE

    Contactor starters
  • PMA
  • PML
  • PME
  • PM12

    Relays


    Thermostatic switches
  • RTL, RTT

    Interposing relays
  • RP-12

    Knife switches
  • Switch disconnectors
  • Disconnecting switches


  • Safety fuses
  • PPN
  • PN2
  • Home > Electrical Equipment > Low-voltage equipment

    Automatic three-phase circuit breakers VA57f35


    Drawings and photographs


    VA 57f35 is a series of automatic circuit breakers that are designed for conducting current under normal conditions and for cutting it off in the event of a short circuit, an overload or an unacceptable voltage drop. In addition, it can be used for infrequent (up to 30 times per day) on and off switching of electric circuits.

      Notation conventions structure:

      VA57-35 - X X XX X X - 20 X3

      VA - device type;

      57 - series number;

      35 - rated current 250 A

      X - number of poles and number of maximum-current release devices:
         3 - 3 poles with maximum-current release devices in each one;
          8 - 2 poles with release devices in two poles, triple-pole construction;
          6 - 3 poles with release devices in two poles;

      X - maximum-current release devices construction, according to protection zone:
         3 - release device in short-circuit current zone;
      4 - release device in short-circuit current and overload current zone;

      XX - auxiliary assembly units combination;

      X - drive type and circuit breaker mounting method:
         1 - hand drive, stationary construction;
           3 - electromagnetic drive, stationary construction;
            5 - remote hand drive, drawout construction;
            7 - electromagnetic drive, drawout construction;

      X - construction according to additional mechanisms:
         0 - no mechanisms;
         5 - remote hand drive for operation through the distribution device door;
      6 - "OFF" position locking device for stationary construction circuit breaker;

      20 - circuit breaker protection rate, according to GOST 14255-69: IP20;

      H3 - climatic construction and placement category, according to GOST 15150-69: UHL4, T3.


    Specifications VA 57-35 VA 57F35
    Circuit breaker rated current (In), A 250 250
    Rated current of the thermal overload release devices, A 16; 20; 25; 31.5; 40; 50; 63; 80; 100; 125; 160; 200; 250
    AC voltage / frequency, V/Hz
    DC, V
    660 / 50-60
    440*
    380 / 50-60
    220
    Maximum switching capacity, kA
    under voltage U and cos j
    3.5 ¸18
    under 660; 0.3
    3.5 ¸ 10
    under 380
    Switching wear resistance, On/Off cycles 4000
    Weight, kg 3.3
             
    Search
    Type one or more keywords
     

    Site map
    Services offered to our clients
    Place an order
    Here you can place an order or ask our experts a question.