automatic two-phase circuit breakers AP50B-2MT
 
Low-voltage equipment

Automatic circuit breakers

Single-phase
  • AE1031
  • AE2044
  • A63M

    Two-phase
  • AP50B-2MT

    Three-phase
  • A3716, A3726
  • A3790
  • AE20
  • VA51, VA52
  • VA57f35
  • AP50B-3MT

    For DIN devices
  • VA6026
  • IEK VA4729

  • Contactor switches
  • KT60

    Break switches

    Button switches
  • KE

    Rotary switches
  • PV, PVP

    Terminal (position) switches
  • VPK
  • VPU

    Push-button control stations
  • PKT
  • PKE

    Contactor starters
  • PMA
  • PML
  • PME
  • PM12

    Relays


    Thermostatic switches
  • RTL, RTT

    Interposing relays
  • RP-12

    Knife switches
  • Switch disconnectors
  • Disconnecting switches


  • Safety fuses
  • PPN
  • PN2
  • Home > Electrical Equipment > Low-voltage equipment

    Automatic two-phase circuit breakers AP50B-2MT


    | Drawings


    AP 50B-2MT is a family of automatic circuit breakers that are designed for overload and short-circuit protection in electric circuits with voltages of up to 220 V DC and up to 500 V AC 50-60 Hz. They are also designed for routine on and off switching of these circuits, 6 to 30 times per day, including electric motor starts, protection and shutdowns.


    SPECIFICATIONS AP 50B2M AP 50B2MT
    Rated voltage, V
        AC 50-60 Hz
        DC
     
    500
    220
     
    500
    220
    Circuit breaker rated current (In), A 63 63
    Rated current of thermal overload release, A 1.6; 25; 4; 6.3; 10; 16; 25; 40; 50; 63
    Momentary response current
    settings, I/In
     
    3; 5 and 10
     
    3; 5 and 10
    Thermal release devices specification:
    do not trigger under a current of 1.05 In
    trigger under a current of 1.35 In
     
     
     
    <1 h
    <0,5 h
    Maximum switching capacity, kA
    under voltage U and cos j
    0.3¸÷ 6 under 380
    0.3÷3.5 under 500
    0.3÷ 6 under 380
    0.3÷3.5 under 500
    Switching wear resistance, On/Off cycles 250 under 12 In 250 under 12 In
    50,000 (for 1.6÷10 A)
    25,000 (for 16; 25 A)
    20,000 (for 40 ÷ 63 A)
    Dimensions, mm
    (overall/mounting)
    width
    height
    depth
     
     
    81/57
    138.5/116
    108.5
     
     
    81/57
    138.5/116
    108.5
    Weight, kg 1.0 1.0
    Mounting method on the board on the board

             
    Search
    Type one or more keywords
     

    Site map
    Services offered to our clients
    Place an order
    Here you can place an order or ask our experts a question.

    E-mail addresses for sales departments:
    machinery department office@mrmz.ru
    electrical equipment department electro@mrmz.ru

    Moscow representative office
    Address and driving directions

    The company
    Address and driving directions
    Services offered to our clients

    Terms of supply

    Rambler's Top100 Rambler's Top100