    Dust separation units




    The UVP plants are designed for:
    In woodworking for removing the cutting waste, sawdust and wood dust (chip blowers).
    Removing the cutting waste during the manufacturing of plastic/aluminum doors and windows.
    For purification of polluted air and returning it into the room during the production of construction materials, during stone dressing, during the manufacturing of food products and during materials handling.
      The use of chip blowers will allow:

    • Decreasing heat losses by up to 100%: due to the elimination of traditional exhaust ventilation by means of its full or partial replacement with the UVP plants.
    • Saving up to 40% of electricity due not only to the reduction of blowing ventilation expenses but also to the connection of the chip blower motor to the machine's start button.
    • Cleaning the air with the filter: removing dust and cutting waste sized 5 microns and above.
    Specifications1500P120015001500U250050007000
    Throughput, m3/hour2000120020002000300050007000
    Input air flow velocity,
    m/s, above
    28202828222228
    Expansion pressure, Pa1500120015001500150018001900
    Air separation efficiency, %99.999.999.999.999.999.999.9
    Air duct diameter, mm16012016080, 120,
    160
    160160160
    Number of air ducts, pcs.1113234
    Number and volume
    of dust collecting bags,
    pcs. x m3
    -1x0.11x0.21x0.32x0.23x0.24x0.2
    Plant's overall dimensions
    , mm
    620x540
    x600
    850x550
    x1800
    970x580
    x2300
    940x650
    x2300
    1600x580
    x2300
    2500x1100
    x2300
    3000x1100
    x2300
    Weight, kg2850686087140160
    Electric motor power, kW1.51.11.51.52.24.05.5

    Recommendations on using individual chip blowers for woodworking equipment

    Individual recirculating chip blowers with throughput of 1200 m3/hour (UVP-1200), 2000 m3/hour (UVP-1500), 3000 m3/hour (UVP-2500), 5000 m3/hour (UVP-5000) and 7000 m3/hour (UVP-7000) are designed for:

  • removing cutting waste during the manufacturing process;
  • air purification (filtering) and returning that air to the room.


  • UVP-1200 and UVP-1500 chip blowers are designed to be used with the following woodworking equipment:
    •  CA-2A, PCK5-2, LS80-6, FSSh-1A, FSh, UFS-1, KF-40, SF4-1, SF6-1, S2F-3, ShPA-40, SP-4, 6P6, SP-8, CDK5-3, SMZ, SVPG-2A, CDK 4-3, C 6-2, VB 12, C-40, CPA-40, LS-40, VFK-2, SVA-2A, SVPG-1, SV1TG-2, SVPG-3, ShLH-2,  KPA-20, CDA-4, VB-12, VB-28, ALTENDORF;
    • for simultaneous operation of two machines, provided that the total volume of exhausted air does not exceed 2000 m3/hour.
    UVP-2500 chip blower is designed to be used with the following woodworking equipment:
    •  ShO 10-4, ShO 16-4, CTZF-1;
    • for simultaneous operation of two or three machines, provided that the total volume of exhausted air does not exceed 3000 m3/hour.
    UVP-5000 chip blower is designed to be used with the following woodworking equipment:
    • for simultaneous operation of two or more machines, provided that the total volume of exhausted air does not exceed 5000 m3/hour.
    UVP-7000 chip blower is designed to be used with the following woodworking equipment:
    •  CMP-2, S10-3, S16-1A, S16-4A, S26-2M, S25-4A, S25-5A, S-125, USCh-1, SCh-4, DKS170-05, DSh-300;
    • for simultaneous operation of two or more machines, provided that the total volume of exhausted air does not exceed 7000 m3/hour.
    NOTES:
    • UVP-1200, UVP-1500 and UVP-2500 are transportable plants that are capable of operating either in stationary or mobile mode where they are consecutively reconnected from one machine to another.
    • UVP-7000 and UVP-5000 chip blowers are basically designed for stationary operation;
    • The use of individual chip blowers IS NOT PROHIBITED by preventive firefighting regulations;
    • Chip blowers are NOT DESIGNED FOR operation with GRINDING equipment that produces explosive gas-dust mixtures during operation;
    • All these plants are designed for PROFESSIONAL use and can be operated CONTINUOUSLY;
    • To increase the EFFICIENCY of the chip blower, it is advisable to connect its motor in parallel to the start button of the machine with which it operates in combination;
    • The equipment cost associated with the UVP plants is 4 to 6 times less than that of traditional ventilation system;
    • Use of these UVP plants helps to reduce the noise caused by waste transportation through air ducts;
    • The UVP plant can be quickly reconnected from one machine to another during the course of work.

             
    Search
    Type one or more keywords
     

    Site map
    Services offered to our clients
    Place an order
    Here you can place an order or ask our experts a question.

    E-mail addresses for sales departments:
    machinery department office@mrmz.ru
    electrical equipment department electro@mrmz.ru

    Moscow representative office
    Address and driving directions

    The company
    Address and driving directions
    Services offered to our clients

    Terms of supply

    Rambler's Top100 Rambler's Top100