OSM
OSM1 OSVMOSO-0.25OSOV-0.25TSZI
TDM-301TDM-401TDM-503
Oil: OMP,
TMGKiosk
substations
Single-phaseThree-phaseElectronic
Movable:
ED8,
16, 30, 60, 100 ED100,
ED200 ED630,
ED1000 Stationary: AD8S,
16S, 30S, 60S, 100 AD8C
emergency AD200S,
AD315S, AD
and ADS Low-power: gasoline,
diesel
|
|
Home > Electrical
Equipment > Transformers and stabilizers Package
kiosk-type transformer substations
Package terminal- and double-ended type 63 to 400 kilovolt-ampere
6 (10) kV transformer substations Package transformer substations represent
outdoor, single-transformer substations that are designed for the intake of three-phase
50 Hz, 6 or 10 kV AC, for its transformation to 0.4 kV electrical energy and for
its supply to consumers in temperate climate districts (-40°C to +40°C).
These substations are available with either cable or aerial inlets and outlets
in different combinations. When an aerial inlet is used, the transformer substation
is connected to the power line by means of a disconnecting switch (supplied with
the substation), which is installed on the nearest pole. Stationary, automatic
circuit breakers are installed on the package transformer substations' outgoing
lines. The high-voltage fuse holders are installed inside the package transformer
substation's cabinet. These substations keep record of the active electrical energy.
These package transformer substations contain both electric and mechanical blocking
devices that ensure the maintenance staff's safety. These package transformer
substations also have an outdoor lighting feeder that turns on and off automatically.
The system includes the necessary heating to create suitable operating conditions
for low-voltage equipment.
- Terminal-type transformer substation - KTPT
- Double-ended type transformer
substation - KTPP
SPECIFICATIONS | KTP
63 | KTP 100 | KTP 160 | KTP
250 | KTP 400 | Transformer
type | TMG |
Transformer rated output, kilovolt-ampere |
63 | 100 |
160 | 250 |
400 | Transformer
winding connection and group reference | Y/Yn-0 |
Y/Yn-0; Δ/Yn-11 |
Rated voltage on the high-voltage side, kV |
6 | 10 |
6 | 10 |
6 | 10 |
6 | 10 |
6 | 10 |
Fuse interrupting rating on the high-voltage
side, A | 16 | 10 |
20 | 16 |
31.5 | 20 |
50 | 31.5 |
80 | 50 |
Rated voltage on the low-voltage side,
kV | 0.4 |
Rated current of the outgoing line, A | ?1 |
25 | 40 |
80 | 100 |
? 2 | 25 |
40 | 80 |
100 | 160 |
? 3 | 63 |
100 | 160 |
200 | ?
4 | 40 | 80 |
100 | 160 |
200 | ?
5 | 40 |
? 6 | 63 |
street lighting |
16; 25 |
KTPT | L, mm | Weight
with the transformer, kg | with
cable inlet | 3150 | 3350 |
with aerial inlet | 2500 | 2850 |
Back
| | Search | |
Services offered
to our clients | |
Services offered
to our clients | |
|